Coefficients m1, m2
Load type coefficient m1 :
- | for service load | 0.7 |
- | for extreme load | 1.0 |
Shaft protection coefficient m2 :
- | for concreting in a dry shaft or underwater | 1.0 |
- | for concreting with bentonite slurry | 0.9 |
- | for PVC sheet pile protection (thickness over 0.7 mm) | 0.7 |
- | for sheet pile protection and B system mesh | 0.5 |
- | for steel casing tube protection | 0.15 |
Literature:
Masopust, J., Glisnikova, V.: Zakladani staveb Modul M01. 1st edition, Brno, AN CERM, 2007, 182 p., ISBN 978-80-7204-538-9.