Programa:
Idioma:

CSN 73 1004

The solution is based on Czech standard CSN 73 1004, where the bearing capacity of foundation soil is given by the formula:

with dimensionless coefficients:

where:

cu

-

total cohesion of the soil

B'

-

effective width of the foundation

L'

-

effective length of the foundation

A'

-

effective area of the footing bottom

H

-

horizontal force

q

-

overburden pressure at the level of foundation base

Literature:

CSN 73 1004 (July 2020)